Tier-4 Data Center

The more "mission critical" the application is, the more redundancy, robustness and security required. Data centers are classified by Tiers, with Tier 1 being the most basic and inexpensive, and Tier 4 being the most robust and costly. According to definitions from the Uptime Institute and TIA-942 (Telecommunications Infrastructure Standard for Data Centers), a Tier 1 data center is not required to have redundant power and cooling infrastructures. It needs only a lock for security and can tolerate up to 28.8 hours of downtime per year. In contrast, a Tier 4 data center must have redundant systems for power and cooling, with multiple distribution paths that are active and fault tolerant. Furthermore, access should be controlled with biometric readers and single-person entryways, gaseous fire suppression is required, the cabling infrastructure should have a redundant backbone, and the facility can permit no more than 0.4 hours of downtime per year.


Multi-Homed Connection and Intelligent Routing

AmeriHosting is directly connected to 9 Tier-1 providers, including Verizon, AT&T, Qwest, Level(3), Sprint, Cable & Wireless, Digex, NTT/Verio, and Global Crossing providing the best speed and redundancy possible. Our Intelligent Routing Technology selects the best path out of 9 major backbones and gets your data get from point A to point B in the fastest, most reliable, and least-congested path possible.

Premises

  • The Facility is housed in a poured concrete building, making it resistant to natural disasters.
  • State-of-the-Art security monitoring system include intelligent card access, fingerprint scanners, and even retinal eye scanners in addition to 24x7 video surveillance.

Force-Filtered Cooling

All the drives, motherboards, and power supplies of our computers are in cases with a positive pressure filtered air environment. Two large fans pull air into the protective case through filters, and the components within are cooled by fans which circulate this purified air. The constant introduction of clean air into the case creates a positive pressure environment, ensuring that dust and particulates are swept out and never in. Raised floors push air up through force filtered-air up through server cabinets.

Environmental controls

  • Multiple Liebert HVAC systems provide air conditioning and humidification control, maintains a constant temperature of 65°F and a humidity level that does not exceed 55%.
  • Our fire suppression system not only prevents extensive fire damage, it virtually eliminates the potential for collateral damage to delicate equipment from the fire extinguishing agent. Multi-level alarms allow floor attendants to investigate when the Very Early Smoke Detection Apparatus (VESDA) system detects a smoke signature. The smoke signature detection system constantly monitors the data center for specific events and can pinpoint the physical location of an event immediately upon detection. An FM200 fire suppression system handles individual instances on the data center floor.
Power Redundancy

  • The facility has a three stage monitored power redundancy system.
  1. Separate power grids.
  2. Constant Power Supply (CPS) System.
  3. Multiple Diesel generators (infinite power).
  • To provide uninterrupted power supply to the data center, we use an environmentally-friendly power supply system that incorporates a steady stream of power from the local utility company and back-up power using a state of the art constant power supply (CPS) and diesel generators. With the CPS system we use, there is no need for battery operated uninterruptible power supply (UPS) units. Instead, our short term backup power supply is completely generated from flywheel systems and then power sustained using diesel generators for long-term backup power. On-site fuel supplies ensure power availability for days at a time. Contracts with multiple local fuel suppliers allow us to provide power indefinitely.

Facility Equipment

  • All servers connected to our network via Fast Ethernet (100MB/second).
     
  • The facility backbone consists of Foundry Gigabit switches, Cisco Catalyst switches and Cisco routers.
     
  • Full Tape Backup System on network with daily backups.
 